Human ACTG1 ELISA KIT
Packing 96Tests
FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ ENTIRE PROCEDURE!
Gene Name ACTG1
Protein Name Actin, cytoplasmic 2
Alternative Name
Human ACTG1 ELISA KIT , Human ACT ELISA KIT ,Human ACTG ELISA KIT ,Human DFNA20 ELISA KIT ,Human DFNA26 ELISA KIT ,Human HEL-176 ELISA KIT ,Human actin cytoplasmic 2 ELISA KIT ,Human cytoskeletal gamma-actin ELISA KIT ,Human epididymis luminal protein 176 ELISA KIT ,Human actin gamma 1 ELISA KIT ,Human actin gamma ELISA KIT
Intended use
Human ACTG1 ELISA KIT allows for the in vitro quantitative determination of ACTG1 concentrations in serum, plasma, tissue homogenates, cell culture supernates or other biological fluids.
| Reagent | Quantity |
| Assay plate | 1 |
| Standard | 2 |
| Sample Diluent | 1 × 20mL |
| Assay Diluent A | 1 × 10mL |
| Assay Diluent B | 1 × 10mL |
| Detection Reagent A | 1 × 120μL |
| Detection Reagent B | 1 × 120μL |
| Wash Buffer(25 x concentrate) | 1 × 30mL |
| Substrate | 1 × 10mL |
| Stop Solution | 1 × 10mL |
| Plate sealer | 5 |
Test principle
The microtiter plate provided in Human ACTG1 ELISA KIT has been pre-coated with an ACTG1 antibody specific to ACTG1. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific for ACTG1 and then avidin conjugated to Horseradish Peroxidase (HRP)is added to each microplate well and incubated. Then a TMB substrate solution is added to each well. Only those wells that contain ACTG1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of ACTG1 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Sample collection and storage
Serum - Use a serum separator tube (SST)and allow samples to clot for 30 minutes before centrifugation for 15 minutes at approximately 1000 × g. Remove serum and assay immediately or aliquot and store samples at -20
Technical Principle & Methodology
The quality assurance and experimental performance of this biological reagent are rigorously optimized and standardized according to its specific technical pathway:
Double Antibody Sandwich Method
(双抗体夹心法). This ensures maximum reproducibility across clinical research and scientific workflows.