Human Filamin-A-interacting protein 1, FILIP1 ELISA Kit
The Human FILIP1 ELISA Kit (Catalog ELI-44006H) is a two-site sandwich immunoassay for the quantitative determination of human Filamin-A-interacting protein 1 in serum, plasma and other biological fluids. It covers a detection range of 78.1-5000 pg/mL with a sensitivity of 39 pg/mL. Pre-coated capture antibody, biotinylated detection antibody, streptavidin-HRP and TMB readout at 450 nm give reproducible measurement of this cytoplasmic filamin-A-binding protein that regulates neocortical neuron migration via the actin cytoskeleton.
Product Description
For the quantitative detection of Human Filamin A-interacting protein 1 (FILIP1) concentration in serum, plasma and other biological fluids.
Target Background
FILIP1 (filamin A-interacting protein 1, also known as KIAA1275) is a cytoplasmic protein that binds filamin A and controls the initiation of neocortical neuron migration from the ventricular zone through a filamin-A/F-actin axis. The protein contains an N-terminal region with coiled-coil and leucine-zipper motifs and may promote filamin A degradation. It localizes to the cytoplasm and cytoskeleton and is expressed in heart, brain and muscle, where it links actin dynamics to cell polarity and motility during cortical development.
Ordering Information
| Catalog No. | Product Name | Target Species | Size | Availability |
|---|
| ELI-44006H | Human Filamin-A-interacting protein 1, FILIP1 ELISA Kit | Human | 96T | Upon request |
Technical Specifications
| Catalog Number | ELI-44006H | Target Biomarker | Human Filamin-A-interacting protein 1, FILIP1 protein |
| Assay Methodology | Sandwich ELISA Kit | Subcellular Location | Cytoplasm, Cytoskeleton |
| Detection Range | 78.1-5000 pg/mL | Sensitivity | 39 pg/mL |
| Validated Samples | serum, plasma, tissue homogenates, cell lysates and other biological fluids | Gene Name | FILIP1 (also known as FILIP, KIAA1275; NCBI Gene ID 27145) |
| Chromosomal Location | Chromosome 6 (Homo sapiens) | UniProt ID | Q7Z7B0 |
| Alternative Names | FILIP1, FILIP, KIAA1275, filamin A-interacting protein 1 | |
Assay Principle
This assay employs a two-site sandwich ELISA to quantitate FILIP1 in Human serum, plasma. An antibody specific for FILIP1 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any FILIP1 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for FILIP1 is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of FILIP1 bound in the initial step. The color development is stopped and the intensity of the color is measured.
Standard Curve and Detection Limit
The assay quantitation range is 78.1-5000 pg/mL and the minimum detectable dose (sensitivity) is 39 pg/mL. The standard curve was generated from the following concentrations: 5000, 2500, 1250, 625, 312.5, 156.2, 78.1 and 0 pg/mL.
Assay Specificity
This assay has high sensitivity and excellent specificity for detection of Human FILIP1. No significant cross-reactivity or interference between Human FILIP1 and analogues was observed.
Validation Data & Performance
5.1 Recovery
| Sample Type | Number | Recovery Range (%) | Average (%) |
|---|
| Kit-specific recovery data are not included in the source product specification provided for this assay. Spike-recovery figures for your lot are published in the product manual available from the download banner above; always refer to the manual shipped with the kit. |
5.2 Linearity
| Sample Type | 1:2 (%) | 1:4 (%) | 1:8 (%) | 1:16 (%) |
|---|
| Kit-specific dilutional linearity data are not included in the source product specification provided for this assay. Dilution-recovery figures for your lot are published in the product manual available from the download banner above; always refer to the manual shipped with the kit. |
5.3 Precision
| Precision Type | Replication Design | n | CV (%) |
|---|
| Intra-Assay | Same sample, 20 replicates on one plate | 20 | CV < 8% |
| Inter-Assay | Same sample, 40 separate assays | 40 | CV < 12% |
CV (%) = SD/mean x 100. Three samples of known concentration were tested.
Key Features & Benefits
- Two-site sandwich format: The microplate is pre-coated with a capture antibody specific to Human Filamin-A-interacting protein 1, FILIP1 protein, and detection uses a biotin-conjugated antibody with streptavidin-HRP amplification, so color develops in proportion to the amount of target bound in the initial step.
- Broad dynamic range: Quantify Human Filamin-A-interacting protein 1, FILIP1 protein across 78.1-5000 pg/mL with a sensitivity of 39 pg/mL, suited to both high- and low-abundance samples.
- Multiple sample types: Validated for serum, plasma, tissue homogenates, cell lysates and other biological fluids, supporting flexible experimental designs.
- Target specificity: Antibodies are raised against Human Filamin-A-interacting protein 1, FILIP1 protein and the analyte is referenced to FILIP1 (UniProt Q7Z7B0, chromosome 6), reducing cross-reactivity with unrelated proteins.
- Research-grade quality: Each lot is manufactured under controlled processes and the assay is intended for research use only (RUO).
- Published target: FILIP1 is an established research target in cortical neuron migration and neurodevelopment, filamin-A/actin cytoskeletal signaling, dendritic spine morphology and excitatory neurotransmission, and cancer cell motility; see the scientific literature section for representative PubMed references.
Scientific Literature & References
- Nagano T, Yoneda T, Hatanaka Y, Kubota C, Murakami F, Sato M (2002). Filamin A-interacting protein (FILIP) regulates cortical cell migration out of the ventricular zone. Nat Cell Biol, 4(7):495-501. PubMed ID: 12055638
- Nagano T, et al. (2004). Filamin A and FILIP (Filamin A-Interacting Protein) regulate cell polarity and motility in neocortical subventricular and intermediate zones during radial migration. J Neurosci, 24(43):9641-9650. PubMed ID: 15509752
- Mungall AJ, et al. (2003). The DNA sequence and analysis of human chromosome 6. Nature, 422(6934):489-495. PubMed ID: 14574404
Academic FAQ
What is FILIP1 protein?
FILIP1 encodes Human Filamin-A-interacting protein 1, FILIP1 protein, a protein localized to the cytoplasm and cytoskeleton, where it associates with filamin A and F-actin to regulate cell migration and polarity.. The gene is annotated in the reference genome on chromosome 6 (Homo sapiens) and the encoded protein is listed in UniProt under accession Q7Z7B0. The protein participates in FILIP1 encodes filamin A-interacting protein 1, a cytoplasmic protein that binds filamin A and controls the initiation of neocortical neuron migration from the ventricular zone through a filamin-A/F-actin axis; it may also promote filamin A degradation. The protein contains coiled-coil and leucine-zipper regions and localizes to the cytoplasm and cytoskeleton, linking actin dynamics to cell polarity and motility during cortical development.. It is expressed across multiple tissues, with abundance varying according to physiological state and differentiation stage. Quantifying FILIP1 by a sandwich ELISA provides an orthogonal readout to Western blotting or transcript-based methods and is well suited to screening many samples in parallel. Because the assay measures the protein rather than its messenger RNA, it reports the functional endpoint more directly and is less sensitive to post-transcriptional regulation. For absolute quantitation, unknown samples should be interpolated from the same standard curve used on the plate and, where cross-sample comparison matters, normalized to total protein content or cell number.
How does the Sandwich ELISA principle work?
A sandwich ELISA uses a microtiter plate pre-coated with a capture antibody specific to the target protein. Standards and unknown samples are added to the wells so the target binds to the immobilized capture antibody during an incubation step, after which unbound material is removed by washing. A biotin-conjugated detection antibody is then added; it binds a second, distinct epitope on the captured protein, forming an antibody-target-antibody sandwich. Streptavidin conjugated to horseradish peroxidase (HRP) is added and binds the biotin on the detection antibody. Following another wash to remove excess conjugate, the TMB substrate is added; HRP oxidizes colorless TMB into a blue product that turns yellow when the reaction is stopped with sulfuric acid. Absorbance is measured at 450 nm, typically with a reference wavelength near 570 nm, and the target concentration in each sample is derived by fitting the optical density to a four-parameter logistic standard curve run on the same plate. Interpolation from this curve converts absorbance into absolute concentration.
Which sample types are compatible with this kit?
The kit is validated for serum, plasma and other biological fluids. For serum, allow blood to clot at room temperature before centrifugation; for plasma, collect into an anticoagulant such as EDTA or heparin and centrifuge promptly. Spin samples at 1000 x g for 15-20 minutes and transfer the clear supernatant, avoiding the cellular pellet. Other biological fluids should be centrifuged to remove particulates and assayed immediately or stored in aliquots. To preserve analyte integrity, avoid repeated freeze-thaw cycles and store aliquots at -20 C or -80 C, thawing each aliquot only once immediately before use. Samples intended for use within five days may be held at 2-8 C; longer storage requires -20 C or -80 C. Hemolyzed specimens can shift the measured value and are not suitable for the assay. Bring every sample to room temperature before pipetting, and where cross-sample comparison matters normalize results to total protein content so that differences in abundance are not confounded by variations in sample loading.
What are the storage requirements for this kit?
Unopened kits should be stored at 2-8 C and protected from light; under these conditions the reagents remain stable until the expiry date printed on the box. After opening, the pre-coated microplate should be resealed inside its moisture-barrier pouch together with the desiccant and returned to 2-8 C, while liquid components such as the standard, HRP conjugate and TMB substrate are kept at their indicated temperatures and shielded from direct light. Some reagents, including the concentrated wash buffer, may precipitate or appear turbid at low temperature; warm them to room temperature and mix gently before use. The TMB substrate and chromogen are particularly light sensitive and should not be exposed to strong illumination. Once reconstituted, standards and conjugates should be used within the timeframe stated in the manual and not carried between lot numbers. Reagents should not be subjected to repeated freeze-thaw cycles; aliquot fragile components when the manual permits and discard any remainder after the recommended holding period. After the color reaction is stopped with the sulfuric acid solution, the resulting optical density remains valid only briefly, and all wells should be read promptly on a 450 nm microplate reader. If any component shows unexpected color, turbidity or reduced signal, discontinue use and consult the troubleshooting section of the manual rather than interchanging parts from a different lot.
What is the difference between FILIP1 and FILIP1L?
FILIP1 and FILIP1L are paralogous members of the filamin A-interacting protein (FILIP) family that both bind filamin A and modulate the actin cytoskeleton. FILIP1 (also called KIAA1275) was the first identified member; it contains N-terminal coiled-coil and leucine-zipper regions and, through the filamin-A/F-actin axis, controls the initiation of neocortical neuron migration from the ventricular zone and influences dendritic spine morphology. FILIP1L (also known as DOC-1/GIP130) is a related paralog with an N-terminal extension and a second isoform of about 1,135 amino acids; it localizes to the cytoplasm, membrane and nucleus and acts as an antiangiogenic regulator of endothelial cells, with tumor-suppressive roles reported in several cancers. The two ELISA kits quantify the species ortholog present in the indicated sample: human FILIP1 (UniProt Q7Z7B0, chromosome 6) and mouse Filip1l (UniProt Q6P6L0, chromosome 16). Despite their shared filamin-A-binding architecture, they are distinct gene products and should not be used interchangeably in quantitation.